A
|
ANALYZERS -
FLUE GAS / NETWORK / AUTOMOTIVE / ENGINE / SPECTRUM
/
ANEMOMETERS - TRANSMITTER
& ADAPTOR /
ASSEMBLY TERMINAL BLOCK / ALCOHOL
TESTERS / ALTI METER
|
|
|
|
|||
|
TPI-712 |
TPI-A740 |
||||
|
Range : -150 mbar ~
+ 150mbar Resolution : 0.01
mbar Accuracy : +0.5% fsd TPI-A740
Infrared Printer : Self test at
Power ON Adjustable
contrast (low, norm, high) Manual paper feed (advance) Power On indication (Red LED) Operates on 4 AA batteries or optional AC adapter |
Gases
: |
Range |
Resolution |
Accuracy |
|
Oxygen
|
0-25% |
0.1% |
+0.3% |
||
|
Carbon Monoxide |
0-10,000 ppm |
1 ppm |
<20
ppm : +3 ppm >100 ppm : +5% |
||
|
Carbon
Dioxide (Calculated) |
0-25% |
0.1% |
+0.3% |
||
|
CO/CO2 Ratio (Calculated) |
0-0.999 |
-- |
-- |
||
|
Combusion Efficiency |
0-100% |
0.1% |
-- |
||
|
Gas Leak Sensor |
100-10,000 ppm |
-- |
-- |
||
|
Measure Earth Reasistance without the need for poles I the ground or external measuring wires. Earth Measurement uses the real earth current path and the current generated by the electric network, without the need for any disconnection. The Earth Resistance displayed is exactly the earth resistance that the earth current will need to go through if an earth fault occurs. Displays voltage supply at the transformer (Line to Neutral). without loading the transformer. |
|||
|
TECHNICAL SPECIFICATION |
TYPICAL ACCURACY |
||
|
Loop Impedance Range L-E, L-N |
0.03-2000V (Software Ctrl) |
Loop Impedance |
4% of FS + 2 dgt |
|
Voltage Measurement
L-N, L-E |
50 to 280V AC (Sine) |
PSC Current |
10% of FS + 5 dgt |
|
PSC current (L-N)
max. |
6KA @ 230V AC supply |
Voltage |
2% of FS + 1 dgt |
|
PSC current (L-E)
max. |
6KA @ 230V AC supply |
Operating /
Temperature |
-10oC to + 40oc / |
|
Operating Voltage |
230V +50% @ 50Hz Sine |
Operating Humidity |
80% max relative humidity |
|
Dimensions (LxWxD) |
(170 x 165 x 92)mm |
|
|
|
Power Source |
6 x AA Batteries |
|
|
|
Simultaneus Display Air Velocity and Temperature Measurement
Range Airflow 80-4900 ft / min, 0.4-30 m / sec. Temperature -10-+50°C, +14-122°F
with max. / min. / Average memory with Data hold function / Temperature
Sensor. Battery Type and Life : 9 Volt./100 hours (under normal usage).
Display Type and Size : LCD 37mmx42mm (11/4 x 15/8).
Max Reading : 9999. Diameter of Fan : 70mm (27/8) with Auto Power Off 20 minutes. Selectable Knot, Mile/H, KM/H. |
|
|
3½ digit LCD display (8mm) Portable, Fast High Accurate
Readability Measurement Range : 0.4-30.0 m/s, 1.4-108 Km/h, 80-5910 f /min, 0.8-58.3Knots
with Data hold function. |
|
|
Same As Above but Temperature Range : 0oC~60oC / 32oF~140oF. Resolution : 0.1oC / oF. |
|
|
|
|||||||||||||
Air Velocity
|
|
||||||||||||
Measurement
|
Range |
Resolution |
Accuracy |
Measurement |
Range |
Resolution |
Accuracy |
||||||
|
m/s |
0.4-25.00 m/s |
0.01 m/s |
+(2%+0.2m/s) |
Km/h
|
1.4-90.0km/h |
0.1 km/h |
+(2%+0.2km/h) |
||||||
|
mile/h |
0.9-55.9 mile/h |
0.1 mile/h |
+(2%+0.2mile/h) |
Knots |
0.8-48.6 knots |
0.1 knots |
+(2%+0.2knots) |
||||||
|
Ft/min |
80-4921 ft/min |
1 ft/min |
+(2%+0.2ft/min) |
|
|||||||||
Air Flow
|
Air Temperature
|
||||||||||||
Measurement
|
Range |
Resolution |
Area |
Measuring Range |
Resolution |
Accuracy |
|||||||
|
CMM (m3/min) |
0-999.900 m3/min |
0.001-100 |
0.001-9,999 m3/min |
0oC ~ 50oC 30oF ~ 122oF |
0.1oC 0.1oF |
0.8oF 1.5oF |
|||||||
|
CFM (ft3/min) |
0-999.900 ft3/min |
0.001-100 |
0.001-9,999 ft3/min |
||||||||||
|
RS-232 Serial Interface. All same as AM-4206 but with Metal Vane Probe, Heavy Duty. |
|
|
Microprocessor circuit
assures maximum possible accuracy, provides special functions and features.
Large LCD with Dual function meters display. Metal vane, heavy duty and wide
range air flow measurement. Records Maximum and Minimum reading with RECALL.
Data Hold. Auto Power OFF. RS-232 Serial Interface. |
|
|||||||
|
Measurement |
Range |
Resolution |
Accuracy |
Measurement |
Range |
Resolution |
Accuracy |
|
|
Temp. (oC) |
0oC~80o |
0.1oC |
+0.8oC(<60oC) |
Temp. (oF) |
32oF~176oF |
0.1oF |
+1.5oF(<140oF) |
|
|
m / s |
0.8~40.0
m/s |
0.1 m/s |
+ (2% +
2d) |
km / h |
2.8~144.0km/h |
0.1k
m/h |
+ (2% +
2d) |
|
|
ft / min |
160~4930
ft/min |
1
ft/min |
+(2% +
20ft/min) |
Knots |
1.6~78.1
knots |
0.1
knots |
+ (2% +
2d) |
|
|
mile / h |
1.8~89.4mile/h |
0.1
mile/h |
+ (2% +
2d) |
|
|
|
|
|
|
AM-4213 MINI VANE ANEMOMETER. Exclusive one-chip
of microcomputer LSI circuit. 13mm (0.5) Super Lace LCD Dual Display. Sensor
Structure : Air Velocity - Conventional twisted van arm and low friction ball
bearing design. Temperature - Thermistor. Data Output : RS-232. |
|||||||
|
Air Velocity |
|||||||
|
Measurement |
Range |
Resolution |
Accuracy |
Measurement |
Range |
Resolution |
Accuracy |
|
m / s |
0.8 ~ 12.00 m/s |
0.01 m/s |
+(2% +
0.2 m/sec) |
km / h |
32oF ~ 176oF |
0.1oF |
+1.5oF (<140oF) |
|
mile / h |
1.8 ~ 26.8 mile/h |
0.1 mile/h |
+(2% +
0.2 mile/h) |
knots |
2.8 ~ 144.0 km/h |
0.1k m/h |
+ (2% +
2d) |
|
ft / min |
160 ~ 2358 ft/min |
1 ft/min |
+(2% +
0.2 ft/min) |
|
|
|
|
|
Air Temperature |
|||||||
|
Temp. (oC) |
0oC ~ 80oC |
0.1oC |
+0.8oC |
Temp. (oF) |
32oF ~ 175oF |
0.1oF |
1.5oF |
|
HATCO AM-4812 DIGITAL ANEMOMETER. 4 Digits LCD
display. Low friction ball-bearing
and carefully balanced vane results in accurate velocity measurement. 4 display mode :
m/s. km/h, ft/min. knots. Data hold for
easy reading. Ideal for use in
checking air conditioning and heating systems, measuring air velocity, wind
speed. Technical
Specification : Air velocity : 0.4~30.0 m/s, +2%+1d.
1.4~108.0 km/h, +2%+3d. 80~5910 ft/min, +2%+2d. 0.8~58. 9
Knots, +2%+2d. Resolution : 0.1 m/s, kn/h, knots or 1 ft/min. Battery
: 1.5V x 4. HATCO AM-4822 DIGITAL ANEMOMETER. All same as AM-4812 but with
Built-in temperature oC / oF measurement. Temperature : 0 ~
60oC, +0.5oC (32 ~ 140oF, +0.9oF). Resolution : 0.1oC / 0.1oF. |
|
|
|
AM-4812 |
AM-4822 |
|
|
|
|
|
|
|
AVM-01 |
AVM-03 |
AVM-05 |
AVM-07 |
|
PROVA AVM-01 ANEMOMETER. 3½ digit LCD
Dispaly. Sensitive of Low / High Air
Velocity. Ergonmic Design. Detached 52mm (diameter) Vane Head. Power Source : 9V
Battery. |
|||||||
|
Measurement |
Range |
Resolution |
Accuracy |
Measurement |
Range |
Resolution |
Accuracy |
|
m / s |
0-45.0 |
0.1 |
+3% or
0.1 |
km / h |
1-140.0 |
0.1 |
+3% or 0.1 |
|
ft / min |
0-8800 |
10 |
+3% or
10 |
Knots |
0-88.0 |
0.1 |
+3% or 0.1 |
|
mile / h (Optional) |
0-100.0 |
0.1 |
+3% or
0.1 |
|
|
|
|
|
PROVA AVM-03 ANEMOMETER. All same as AVM-01
but with Temperature : 0 ~ 60oC (32 ~ 140oF) Resolution : 0.1 Accuracy : +0.8 (+1.5). |
|
PROVA AVM-05 FLOW ANEMOMETER. LCD Dual Display.
Flow (CFM, CMM) Instant / Ave / 2 / 3 / Vmax Flow Measurement Velocity
m/s, ft/min, knots, km/hr, mph Max / Min Hold. |
||||||||
|
Air Velocity |
||||||||
|
Measurement |
Range |
Resolution |
Accuracy |
Measurement |
Range |
Resolution |
Accuracy |
|
|
m / s |
0.4-25.00 m/s |
0.01 m/s |
+(2%+0.2m/s) |
km / h |
1.4-90.0 km/h |
0.1 km/h |
+(2%+0.2km/h) |
|
|
mile/h |
0.9-55.9mile/h |
0.1 mile/h |
+(2%+0.2mile/h) |
Knots |
0.8-48.6knots |
0.1 knots |
+(2%+0.2knots) |
|
|
ft / min |
80-4921ft/min |
1 ft/min |
+(2%+0.2ft/min) |
|
|
|
|
|
|
Air Flow |
Air Temperature |
|||||||
|
Measurement |
Range |
Resolution |
Accuracy |
Measurement Range |
Resolution |
Accuracy |
||
|
CMM (m3/min) |
0-999, 900m3/min |
0.001 - 100 |
0.001-9, 999m3/min |
0oC to 50oC |
0.1oC |
0.8oF |
||
|
CFM (ft3/min) |
0-999, 900ft3/min |
0.001 - 100 |
0.001-9, 999ft3/min |
30oF to 122oF |
0.1oF |
1.5oF |
||
|
PROVA AVM-07 FLOW ANEMOMETER. All same as AVM-05
but with RS-232 & Momory of 2,000 Records. |
|
For very low air
velocity measurement with telescopic probe. Display : Super large 13mm (0.5) LCD with dual function meters
display, read the air Velocity and Temperatire. Build in temperature
Thermistor sensor for oC, oF measurement for Precision fast response. Applications :
Environmental Testing, Air conveyors, Flow hoods, Clean rooms, Air veloc ity,
Air balancing, Fans motors/ blowers, Furnace velocity, Refrigerated case,
Paint spray booths. Circuit : Custom one-chip of micro-processor LSI circuit.
Memory : Maximum and Minimum with recall and Data hold. Auto Power shut off. |
|
|
Dual digits LCD
with function annunciation. Measurement - Air Velocity : m/s, km/hr, ft/min,
knots, mile/s. Temperature : oC, oF. Measurement Range - Air Velocity : 0.2~20 m/s. (*Sensor : Glass
bead Thermistor). Temperature : -5oF~175oF (-20oC~80oC). Powering : 1.5V x 6 (AAA TYpe) Alkaline Battery. |
|
||||||
|
Measurement |
Range |
Resolution |
Accuracy |
Measurement |
Range |
Resolution |
Accuracy |
|
m / s |
0.2~20.0 |
0.1 |
+5% of reading +3dgt |
ft / min |
40~3940 |
1 |
|
|
km / h |
0.7~72.0 |
0.1 |
Temperature |
-20oC~80oC |
0.1 |
+1% of reading +0.5oC +3
digit |
|
|
mile / h |
0.5~44.7 |
0.1 |
-5oF~175oC |
+1% of reading +1.0oC +3
digit |
|||
|
knots |
0.4~38.8 |
0.1 |
|
|
|
|
|
|
Dual digits LCD with function annunciation. Data Hold, Auto Power
Off, Data record function for Max and Min. Temperature and Air Velocity
reading. Measurement : m/s, km/s, ft/min, knots, mile/h, oC, oF. Measurement Range And Accuracy : Air Flow
(Vane) - 0.4 ~ 25m/s (+2% of reading +3 digits). Hot
Wire : 0.2 ~ 20 m/s (+5%
of reading +3 digits). Temperature : -20oC~ 80oC (+1% of reading +0.5oC +3digit), -5oC ~ 175oF (+1%
of reading +1.0oF +3 digit). |
|
|
To cooperate with
DMM 200mV range be used as an Anemometer to check air conditioning &
heating systems, measure air velocities, wind speeds etc. Measure Range : 0.4~30.0 m/s, 1.4~108.0 km/h, |
|
|
JZ-712 / JZ-713 STAND FOR ANEMOMETER, SOUND LEVEL METER,
VIBRATION METER AND INFRARED THERMOMETER. |
|
|
|
||||||
|
Model |
|
|
|
|
|
|
|||
|
JZ-712 |
50g |
105mm |
f10mm |
140mm |
105mm |
0.8kg |
|||
|
JZ-713 |
30g |
105mm |
f10mm |
140mm |
105mm |
0.8kg |
|||
Model
|
HYBT-15
|
HYBT-15-2
|
HYBT-25
|
HYBT-35
|
HYBT-60
|
HYBT-100
|
|
APPEARANCE
|
|
|
|
|
|
|
|
Rated Insulating Voltage
|
600V
|
||||||
Rated Current
|
15A
|
15A (2 Stack)
|
25A
|
35A
|
60A
|
100A
|
|
|
Insulated Resistance |
100MOhms above |
||||||
Dielectric Strength
|
AC2500V for 1minute
between non-current carrying parts
|
||||||
Terminal Bolt
|
M3.5
|
M4
|
M6
|
||||
Connecting
Terminal |
l (above)
|
8.0mm
Min. |
14.0mm
Min. |
14.5mm
Min. |
20.5mm
Min. |
||
d (above)
|
f 3.6 Min. |
f 4.1 Min. |
f 6.1 Min. |
||||
|
W (max) |
6.8mm
Max. |
8.7mm
Min. |
9.6mm
Min. |
12.4mm
Min. |
16.5mm
Min. |
||
|
L (above) |
20.0mm
Min. |
27.0mm
Min. |
30.0mm
Min. |
45.0mm
Min. |
|||
HYBT(02~03)
|
HYBT(12)
|
HYBT(07)
|
HYBT(08)
|
HYBT(10)
|
|
|
|
|
|
|
Separator
|
Separator
|
Stopper
|
Cover
|
Number Plate
|
|
ROAD Test Alcohol Breath Tester. Unique 4 digits LCD
display Build in DSP microprocessor technology. Warm up time : less
than 20 sec. (typical). Auto adjust / reset, with reset button Illumination button
for use in dark (Auto shut off after 10 seconds) Power source : 1.5V
Alkaline (AA size) x 3. and 12 VDC adapter. Accuracy : 15% @
0.01 % BAC Blowing time : 4 ~ 5 sec. continuously. Automatic switch off
after 30 sec. Removable mouthpiece, easy to clean and replace. CE approved. |
|
|
ABT-168 Alcohol Breath Tester with RS-232 Printer. Sensor : sintered
metal Warm up time: less then 1 min. (typical) Measuring range :
0.000~1.000mg/l BAC (or 0.000~0.200% BAC or 0.000~2.000). Recycle time : 30
seconds (typical) Power supply : 4*
1.5V AAA batteries, 12V AC/DC adaptor (Battery and adaptor not incursive) Back light Display
: photo dot matrix LCD Accuracy : +1/-1 digit Mouth-piece :
individually wrapped disposable w/moisture trap Temperature range :
0°C ~ 45°C. |
|
|
AT 198 ALCOHOL TESTER. Advanced NM Hot-wire
alcohol sensor. Quick response, excellent Accuracy. Smart MCU control. Technical Data :
Detection Range : 0.001-1.00mg / L(0.000~0.20%BAC). Accuracy : +5%
at 0.22mg / L(0.05%BAC). Warm-up Time : <10
sec. (Initial Warm-up : 30 sec). Testing Time : < 8
sec. Display : 3 Digit LCD. Power : 3VDC (2 x AAA
batteries). |
|
SANOH ANALOG ALTI METER 7020 Made
in JAPAN
For CLIMBING, CAMPING and SAILING with BAROMETER, WEATHER FORECAST,
COMPASS, THERMOMETER and MIRROR. Alti Meter Range : 0~5000 Meter. Barometer